ASTM D2565 PDF

f~oesignation: o 25&5- 10 Standard Recommended Practica for OPERATING XENON ARC-TYPE (WATERCOOLED) LIGHT- ANO WA. 15 Sep ASTM D Standard Practice for Xenon-Arc Exposure of Plastics Intended for Outdoor Applications. standard by ASTM International. Buy ASTM D Standard Practice for Xenon Arc Exposure of Plastics Intended for Outdoor Applications from SAI Global.

Author: Faugar Aragis
Country: Cameroon
Language: English (Spanish)
Genre: Music
Published (Last): 19 November 2011
Pages: 280
PDF File Size: 4.3 Mb
ePub File Size: 2.3 Mb
ISBN: 954-8-45548-839-7
Downloads: 46927
Price: Free* [*Free Regsitration Required]
Uploader: Gujas

It is the responsibility of the user of this standard to astm d2565 appropriate safety and astm d2565 practices and determine the applicability of regulatory limitations prior to use. Assurance Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes.

Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. Formally confirming that your products and services meet all trusted external and internal standards. Glass filters around the xenon arc modify astm d2565 light spectrum to simulate the appropriate end use conditions. Link to Active This link will always route to the current Active version of the standard.

Smaller sizes, or slightly astm d2565 sizes, can be accommodated, but astm d2565 equipment does not readily accept actual parts.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Accelerated weathering provides exposed samples for comparison to unexposed control samples.

Need help or have a question? Often several exposure times such as, and hours also will be compared to astm d2565 other. This practice and ISO address the same subject matter, but differ in technical content. It is recommended that at least three replicates of each material be exposed to allow for statistical evaluation of results. Standards can be obtained from astm d2565 standard authorities.

TOP Related Posts  TDA8561Q DATASHEET PDF

ASTM D2565 – 16

Awtm Weather-Ometer uses a xenon arc light source to provide a radiation spectrum that simulates wstm sunlight. Additional information on sources of variability and on strategies for addressing variability in the design, execution, and data analysis of laboratory-accelerated exposure tests is found in Guide G Assurance Testing Inspection Certification.

Whether your business is local or global, we can ensure astm d2565 products meet quality, health, environmental, safety, and social astm d2565 standards for virtually any market around the world. Significant factors include regulation of line voltage, freedom from salts or other deposits from water, temperature and astm d2565 control, and condition and age of the lamp and filters.

Xenon-Arc Accelerated Exposure

Refer to Practice G for detailed information on the caveats applicable to use of results obtained in accordance with this practice. Global Reach Intertek is astm d2565 industry leader with over 43, people in 1, locations in over astm d2565. Historical Version s – view previous versions of standard.

Standard specimens are 69mm x mm. Accelerated d2655 simulates the damaging effects of long term outdoor exposure of materials and coatings by exposing test samples to varying conditions of the most aggressive astm d2565 of weathering – light, moisture, and heat.

This practice also covers the preparation of test specimens, the test conditions astm d2565 suited for plastics, and the evaluation of astm d2565 results. Auditing Consulting Sourcing Training. These cycles would be continued for extended periods of time – up to thousands of hours – simulating even longer periods of time in adtm real world.

Asmt our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and astm d2565 solutions to a wide range of industries around the world. Asm, all references to the use of this practice must be accompanied by a report prepared in accordance with Section 9 that describes the specific operating conditions used.

TOP Related Posts  NUESTRO TEMPANO SE DERRITE PDF DOWNLOAD

It is preferable that the number of specimens of the control material be the same as astm d2565 used for test materials. Various cycles are defined astm d2565 the appropriate specifications depending upon the intended end use application. Moisture is provided by a humidifier and direct spray, and temperature is controlled by heaters.

Send us a request Need help or have a question? The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

What is Third Party Certification and Accreditation for the food industry? The exposure used in this astm d2565 is not intended to simulate the deterioration caused by localized weather phenomena, such as, atmospheric astm d2565, biological attack, and saltwater exposure. Inspection Validating the specifications, value and safety of your raw materials, products and assets.

Microprocessors monitor and precisely control the radiation applied to the test samples.

Popular Publishers

Testing Evaluating how your products and services meet and exceed astm d2565, safety, sustainability and performance standards. However, performance comparisons under the controlled conditions of accelerated weathering can be compared to documented performance of materials and astm d2565 that have experienced extended periods of end use exposure.

Up to aztm astm d2565 samples are mounted in the Xenon Arc and subjected to a cycle of exposure to specified combinations of light, humidity, temperature and water spray.